Development of SC-10: A psychometrically equivalent Singapore Mandarin disyllabic word list for clinical speech audiometry use

SC-10的开发:一种用于临床言语测听的心理测量学等效的新加坡普通话双音节词表

阅读:1

Abstract

OBJECTIVE: The aim of this study is to develop and evaluate a set of psychometrically equivalent disyllabic wordlist (SC-10) in Singapore Mandarin for clinical use. STUDY DESIGN: A preliminary set of 1000 words were obtained from a dictionary of frequently used words by Singapore students. Ten native judges rate the familiarity level of each word. This is followed by a face-to-face public survey to rank the shortlisted word set from most to least familiar. The final 108 disyllabic words were recorded by a native female talker. 20 normal hearing subjects were used to obtain the percentage of correct word recognition at 24 intensity levels (-10 dB HL to 26 dB HL in 2 dB increment). Psychometric function slopes were calculated for each word. 100 words were eventually chosen and assigned into ten 10-word lists based on a psychometric balancing protocol. Minor digital adjustments were made to the intensity of each wordlist to improve their auditory homogeneity.The developed SC-10 wordlists were validated by a separate group of 25 normal hearing subjects. Test-retest reliability was carried out on 20 out of 25 participants at the selected intensity levels (SRT-5, SRT, SRT+5). RESULTS: The calculated regression slopes in the psychometric functions for the ten lists are between 8.0 and 9.8%/dB. Single factor ANOVA analysis showed no significant difference in both the mean intensity required to obtain 50% recognition score (f = 0.109, df = 9, p = 0.999) and the slopes of the psychometric functions (f = 0.078, df = 9, p = 0.999) between the ten word lists. List validation on 25 normal hearing participants (PTA = 11.0 dB HL, SD = 4.3) showed a mean speech recognition threshold (SRT) of 9.3 dB HL (SD = 3.5)and regression slope of 8.395%/dB. Quadratic regression analysis showed a positive correlation (r (2) = 0.923) between presentation level and word recognition score (WRS). The difference between PTA and SRT of each subject all fall within the clinically acceptable difference of 10 dB HL. Test-retest reliability, carried out on 20 subjects at three levels (SRT-5, SRT, and SRT+5 dB), showed no significance difference between word recognition score when the same participant is tested again at the same intensity level using a different wordlist. CONCLUSION: All in all, it shows that the SC-10 speech materials are valid for clinical use for Mandarin speech audiometry in Singapore.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。