Fatal pulmonary embolism following injectable gluteal filler usage: a case report

注射臀部填充剂后发生致命性肺栓塞:病例报告

阅读:1

Abstract

BACKGROUND: Despite the fact that injectable filler usage in the gluteal region has not been recommended in formal medical institutions, illegal procedures are performed in many clinics and beauty centers across Egypt. This case report illustrates the illegal practice culminating in a fatal complication. CASE PRESENTATION: A 26-year-old female with no relevant medical history presented to the ER with acute onset shortness of breath. The complaint started 16 h before, with a rapidly progressive course, shortly after undergoing a gluteal filler injection at a center in Cairo. At ER, the patient was severely distressed, yet fully conscious and oriented. She was shocked (BP 70/40 mmHg), tachycardic (130 BPM), and tachypneic (30/min) with normal temperature. She had congested pulsating neck veins with positive Kussmaul sign. Chest auscultation revealed normal vesicular breathing with equal air entry and no adventitious sounds. Her O2 saturation was 60% on room air that improved to 85% on O2 mask. ECG showed sinus tachycardia. Echocardiography showed dilated right side, D-shaped septum with systolic flattening, dilated IVC, mild tricuspid regurgitation and estimated RV systolic pressure 53 mmHg. Her ABG showed compensated metabolic acidosis with elevated lactate level. At the ICU, CVP was 18 mmHg. Saline infusion was continued along with noradrenaline infusion initiation. A provisional diagnosis of high-risk pulmonary embolism was made, though CT pulmonary angiography was not available. Accordingly, thrombolytic therapy was initiated with alteplase (100 mg) over 2 h. Also, a dose of pulse steroids (methylprednisolone 200 mg) was given. Chest X-ray showed bilateral heterogenous opacity and ABG showed deteriorating hypoxia and combined metabolic and respiratory acidosis. The patient was intubated upon deterioration of conscious level and was put on mechanical ventilation. Her ET tube showed frequent blood-tinged secretions. Echocardiography showed more right-side dilatation that was consistent with deterioration of clinical status. Three hours after admission the patient developed cardiac arrest and died 2 h later. CONCLUSIONS: This case report highlights the dangers associated with injectable filler usage in the gluteal region. Physicians and patients should be aware of the possible complications and how to avoid it.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。