Performance of Automated Machine Learning in Predicting Outcomes of Pneumatic Retinopexy

自动机器学习在预测气动视网膜固定术结果方面的性能

阅读:2

Abstract

PURPOSE: Automated machine learning (AutoML) has emerged as a novel tool for medical professionals lacking coding experience, enabling them to develop predictive models for treatment outcomes. This study evaluated the performance of AutoML tools in developing models predicting the success of pneumatic retinopexy (PR) in treatment of rhegmatogenous retinal detachment (RRD). These models were then compared with custom models created by machine learning (ML) experts. DESIGN: Retrospective multicenter study. PARTICIPANTS: Five hundred and thirty nine consecutive patients with primary RRD that underwent PR by a vitreoretinal fellow at 6 training hospitals between 2002 and 2022. METHODS: We used 2 AutoML platforms: MATLAB Classification Learner and Google Cloud AutoML. Additional models were developed by computer scientists. We included patient demographics and baseline characteristics, including lens and macula status, RRD size, number and location of breaks, presence of vitreous hemorrhage and lattice degeneration, and physicians' experience. The dataset was split into a training (n = 483) and test set (n = 56). The training set, with a 2:1 success-to-failure ratio, was used to train the MATLAB models. Because Google Cloud AutoML requires a minimum of 1000 samples, the training set was tripled to create a new set with 1449 datapoints. Additionally, balanced datasets with a 1:1 success-to-failure ratio were created using Python. MAIN OUTCOME MEASURES: Single-procedure anatomic success rate, as predicted by the ML models. F2 scores and area under the receiver operating curve (AUROC) were used as primary metrics to compare models. RESULTS: The best performing AutoML model (F2 score: 0.85; AUROC: 0.90; MATLAB), showed comparable performance to the custom model (0.92, 0.86) when trained on the balanced datasets. However, training the AutoML model with imbalanced data yielded misleadingly high AUROC (0.81) despite low F2-score (0.2) and sensitivity (0.17). CONCLUSIONS: We demonstrated the feasibility of using AutoML as an accessible tool for medical professionals to develop models from clinical data. Such models can ultimately aid in the clinical decision-making, contributing to better patient outcomes. However, outcomes can be misleading or unreliable if used naively. Limitations exist, particularly if datasets contain missing variables or are highly imbalanced. Proper model selection and data preprocessing can improve the reliability of AutoML tools. FINANCIAL DISCLOSURES: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。