Bilateral Failure of Oxidized Zirconium Implants in Total Knee Arthroplasty

全膝关节置换术中氧化锆植入物双侧失效

阅读:1

Abstract

Oxidized zirconium was first introduced in total hip arthroplasty procedures to merge the strengths of metal and ceramic into one prosthetic. The subsequent adoption of oxidized zirconium (oxinium) for total knee arthroplasty is attributed to the theory of causing less wear on the tibial components compared to the alternative, cobalt chromium. However, the superficial layer of the femoral component is occasionally breached, exposing the softer zirconium substrate. Multiple mechanisms leading to zirconium substrate exposure have been explained, including collateral ligament instability and polyethylene wear. Such a failure may lead to damage to the periprosthetic tissues and often requires a revision procedure. In the current case report, we present a case of bilateral total knee arthroplasty with oxidized zirconium components that resulted in catastrophic failure and subsequent revision with hinged knee prostheses.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。