We present a case with bilateral hematogenous hip periprosthetic joint infection with Enterococci which could be treated successfully with implant retention despite chronification and partial loosening. A debridement and replacement of the modular components was carried out with replacement of a loose acetabular cup on the right side. Considering poor local infection control, antibiotic treatment was enhanced by local application of vancomycin. In the present case, treatment of chronic enterococcal periprosthetic joint infection while preserving the implants was successful despite unfavorable odds. Considering the duration of infection, causative microorganism, and loosening of one of the implants, staged exchange of both hip replacements would have been the standard procedure. This case illustrates that some concepts have to be challenged from time to time.