False-negative synovial alpha-defensin

滑膜α-防御素假阴性

阅读:1

Abstract

We present a case of chronic periprosthetic hip infection diagnosed using the Musculoskeletal Infection Society criteria as the gold standard. The alpha-defensin test was falsely negative. The diagnostic workup of the patient is detailed, along with a discussion regarding the potential reasons behind the misleading alpha-defensin results. To our knowledge, this is the first reported case of a false-negative alpha-defensin test in the setting of an open sinus tract communicating with a culture-positive total hip implant. The alpha-defensin test should be interpreted cautiously, along with all relevant pertinent clinical data. In certain cases, similar to those described here, the Musculoskeletal Infection Society criteria may perform better than this particular biomarker.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。