Performance Tests of HX340 Microalloyed Steel Sheets Joined Using Clinch-Rivet Technology

采用铆接技术连接的HX340微合金钢板的性能测试

阅读:2

Abstract

This paper presents the possibility of forming a pressed joint between two 1.5 mm thick sheets made of HX340 steel. The joint was formed using an additional deformable steel rivet with a hardness of 400HV1. Different distances of rivet pressing below the initial surface of the upper sheet were chosen: 0, 0.15, 0.30, 0.45 and 0.60 (in mm). For the mentioned rivet-pressing distances, forming tests were performed using an "SKB" die with three die depths: 1.45, 1.60 and 1.75 (in mm). Observations and measurements of the characteristic geometric dimensions of the interlock were made. Furthermore, the strength of the clinch-riveted joints was analysed. Changing the depth of the die by 20%, i.e., from h(d) = 1.45 mm to h(d) = 1.75 mm for the same rivet press-in depth (o(f) = 0%), resulted in a 12% reduction in the forming-force value. The maximum load capacity of the joint in the shear test decreased by 3.5% for the mentioned joint variant. The greater the rivet press-in depth used in the joint (o(f)), the greater the value of the interlock size (t(u)). Increasing the value of rivet-pressing depth below the initial surface of the upper sheet from 0 mm to 0.6 mm resulted in an increase in the size of the interlock (t(u)) by 136% (for h(d) = 1.45 mm), by 128% (for h(d) = 1.60 mm) and by 85% (for h(d) = 1.75 mm).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。