Influence of Microbubble Properties and Carrier Frequency on Ultrasound Cavitation-Induced Flow Augmentation

微泡特性和载体频率对超声空化诱导流动增强的影响

阅读:2

Abstract

BACKGROUND: Cavitation of microbubble (MB) contrast agents produces shear-mediated vasodilation and an increase in tissue perfusion. These effects are mediated through endothelial and erythrocyte shear-sensitive pathways. Our aim was to determine whether augmentation of tissue perfusion produced by cavitation is influenced by the deformability of MBs, MB charge-mediated interaction with vascular cells, or ultrasound (US) frequency, which affects MB resonance. METHODS: In mice, highly deformable lipid-stabilized decafluorobutane MBs with neutral or cationic charge, as well as less-deformable MBs (Sonazoid), were administered intravenously during proximal hind limb US (1.3 MHz, mechanical index = 1.3) for 10 minutes. In separate experiments, high-frequency US (7.0 MHz) was compared to low-frequency US. Conditional variables were compared using quantitative contrast-enhanced US perfusion imaging, and bioluminescence assays of shear-mediated adenosine triphosphate release. Beam spatial characteristics and passive cavitation detection response for each MB agent were assessed by calibrated hydrophone. RESULTS: Passive cavitation detection confirmed intended differences in MB deformability. Cavitation at 1.3 MHz increased perfusion in the US-exposed limb by 6- to 8-fold for highly deformable MBs. There were no differences according to MB charge despite evidence for interaction with vascular endothelial cells on intravital microscopy. Cavitation-mediated flow augmentation was lower (4-fold) for less-deformable MBs (P < .05 vs other agents). Flow augmentation was attributable to increases in microvascular flux rate (β-value). Despite producing less flow augmentation, cavitation with the less-deformable MBs produced equivalent endothelial adenosine triphosphate release. Using high-frequency US for cavitation resulted in a 60% to 70% loss of flow augmentation response. CONCLUSIONS: Factors that affect MB resonance such as US frequency and MB deformability influence the degree of flow augmentation achieved by MB cavitation. Alteration of MB charge that enhances interaction with the endothelial cells does not influence cavitation-mediated flow augmentation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。