Improved Quantification of Myocardium Scar in Late Gadolinium Enhancement Images: Deep Learning Based Image Fusion Approach

改进钆增强晚期图像中心肌瘢痕的定量分析:基于深度学习的图像融合方法

阅读:1

Abstract

BACKGROUND: Quantification of myocardium scarring in late gadolinium enhanced (LGE) cardiac magnetic resonance imaging can be challenging due to low scar-to-background contrast and low image quality. To resolve ambiguous LGE regions, experienced readers often use conventional cine sequences to accurately identify the myocardium borders. PURPOSE: To develop a deep learning model for combining LGE and cine images to improve the robustness and accuracy of LGE scar quantification. STUDY TYPE: Retrospective. POPULATION: A total of 191 hypertrophic cardiomyopathy patients: 1) 162 patients from two sites randomly split into training (50%; 81 patients), validation (25%, 40 patients), and testing (25%; 41 patients); and 2) an external testing dataset (29 patients) from a third site. FIELD STRENGTH/SEQUENCE: 1.5T, inversion-recovery segmented gradient-echo LGE and balanced steady-state free-precession cine sequences ASSESSMENT: Two convolutional neural networks (CNN) were trained for myocardium and scar segmentation, one with and one without LGE-Cine fusion. For CNN with fusion, the input was two aligned LGE and cine images at matched cardiac phase and anatomical location. For CNN without fusion, only LGE images were used as input. Manual segmentation of the datasets was used as reference standard. STATISTICAL TESTS: Manual and CNN-based quantifications of LGE scar burden and of myocardial volume were assessed using Pearson linear correlation coefficients (r) and Bland-Altman analysis. RESULTS: Both CNN models showed strong agreement with manual quantification of LGE scar burden and myocardium volume. CNN with LGE-Cine fusion was more robust than CNN without LGE-Cine fusion, allowing for successful segmentation of significantly more slices (603 [95%] vs. 562 (89%) of 635 slices; P < 0.001). Also, CNN with LGE-Cine fusion showed better agreement with manual quantification of LGE scar burden than CNN without LGE-Cine fusion (%Scar(LGE-cine) = 0.82 × %Scar(manual) , r = 0.84 vs. %Scar(LGE) = 0.47 × %Scar(manual) , r = 0.81) and myocardium volume (Volume(LGE-cine) = 1.03 × Volume(manual) , r = 0.96 vs. Volume(LGE)  = 0.91 × Volume(manual) , r = 0.91). DATA CONCLUSION: CNN based LGE-Cine fusion can improve the robustness and accuracy of automated scar quantification. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: 1.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。