Predictors of mitral valve haemodynamics after mitral valve repair for degenerative mitral regurgitation

退行性二尖瓣反流二尖瓣修复术后二尖瓣血流动力学的预测因素

阅读:1

Abstract

OBJECTIVE: Intraoperative predictors of functional mitral valve (MV) stenosis after surgical repair of mitral regurgitation (MR) caused by prolapse remain poorly characterised. This study evaluated the effect of annuloplasty size on postoperative MV haemodynamics during exercise and evaluated predictors of MV hemodynamics. METHODS: 104 patients were randomly assigned to leaflet resection or preservation for surgical repair of MR in the Canadian Mitral Research Alliance CardioLink-2 study. In this post hoc analysis, we compared MV haemodynamics between the two surgical groups and examined the relationship between annuloplasty size and MV haemodynamics 1 year after repair in the combined groups. Echocardiograms were performed at baseline and intraoperatively. Exercise transthoracic echocardiography was performed 1 year postoperatively. Multivariable linear regression analysis was used to identify predictors of exercise MV gradients at follow-up. RESULTS: Mean age of participants was 65±10 years, and 83% were male. Median annuloplasty size was 34 (IQR 32-36). Dividing by the median, 48 (46%) had annuloplasty size of <34 mm and 56 (54%) had ≥34 mm. Mean and peak exercise gradients at 1 year were 11±5 mm Hg and 22±9 mm Hg in <34, and 6±3 mm Hg and 14±5 mm Hg in ≥34 (p<0.001). Rate of residual MR was similar in both groups. In multivariable analyses, annuloplasty size of ≥34 mm was associated with lower mean and peak exercise gradients at 12 months, after adjustment for repair type, age, sex, heart rate and body surface area (β -4.1, 95% CI -6 to -3, p<0.001, and β -7 95% CI -10 to -4, p<0.001, respectively). Intraoperative mean and peak MV gradients by transesophageal echocardiography independently predicted mean and peak resting and exercise gradients at follow-up (p<0.001). Similar results were obtained in both leaflet resection and preservation. CONCLUSION: Annuloplasty size of ≥34 mm is associated with a 4 and 7 mm Hg reduction in mean and peak exercise MV gradients, respectively, 1 year post MV repair regardless of the repair strategy used. Intraoperative TEE MV gradients predict exercise MV gradients 1 year post repair. TRIAL REGISTRATION NUMBER: NCT02552771.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。