Variations in CT Utilization, Protocols, and Radiation Doses in COVID-19 Pneumonia: Results from 28 Countries in the IAEA Study

新冠肺炎患者CT检查使用情况、检查方案和辐射剂量差异:来自国际原子能机构研究的28个国家的结果

阅读:1

Abstract

Background There is lack of guidance on specific CT protocols for imaging patients with coronavirus disease 2019 (COVID-19) pneumonia. Purpose To assess international variations in CT utilization, protocols, and radiation doses in patients with COVID-19 pneumonia. Materials and Methods In this retrospective data collection study, the International Atomic Energy Agency coordinated a survey between May and July 2020 regarding CT utilization, protocols, and radiation doses from 62 health care sites in 34 countries across five continents for CT examinations performed in patients with COVID-19 pneumonia. The questionnaire obtained information on local prevalence, method of diagnosis, most frequent imaging, indications for CT, and specific policies on use of CT in COVID-19 pneumonia. Collected data included general information (patient age, weight, clinical indication), CT equipment (CT make and model, year of installation, number of detector rows), scan protocols (body region, scan phases, tube current and potential), and radiation dose descriptors (CT dose index and dose length product). Descriptive statistics and generalized estimating equations were performed. Results Data from 782 patients (median age, 59 years [interquartile range, 15 years]) from 54 health care sites in 28 countries were evaluated. Less than one-half of the health care sites used CT for initial diagnosis of COVID-19 pneumonia and three-fourths used CT for assessing disease severity. CT dose index varied based on CT vendors (7-11 mGy; P < .001), number of detector rows (8-9 mGy; P < .001), year of CT installation (7-10 mGy; P = .006), and reconstruction techniques (7-10 mGy; P = .03). Multiphase chest CT examinations performed at 20% of sites (11 of 54) were associated with higher dose length product compared with single-phase chest CT examinations performed in 80% of sites (43 of 54) (P = .008). Conclusion CT use, scan protocols, and radiation doses in patients with coronavirus disease 2019 pneumonia showed wide variation across health care sites within the same and between different countries. Many patients were imaged multiple times and/or with multiphase CT scan protocols. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Lee in this issue.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。