Optimization for speed and sensitivity in capillary high performance liquid chromatography. The importance of column diameter in online monitoring of serotonin by microdialysis

毛细管高效液相色谱法的速度和灵敏度优化。柱直径在微透析在线监测血清素中的重要性

阅读:5
作者:Jing Zhang, Yansheng Liu, Andrea Jaquins-Gerstl, Zhan Shu, Adrian C Michael, Stephen G Weber

Abstract

The speed of a separation defines the best time resolution possible in online measurements using chromatography. The desired time resolution multiplied by the flow rate of the stream of analyte being sampled defines the maximum volume of sample per injection. The best concentration sensitivity in chromatography is obtained by injecting the largest volume of sample that is consistent with achieving a satisfactory separation, and thus measurement accuracy. Taking these facts together, it is easy to understand that separation speed and concentration sensitivity are linked in this type of measurement. To address the problem of how to achieve the best sensitivity and shortest measurement time simultaneously, we have combined recent approaches to the optimization of the separation itself with an analysis of method sensitivity. This analysis leads to the column diameter becoming an important parameter in the optimization process. We use these ideas in one particular problem presented by online microdialysis sampling/liquid chromatography/electrochemical detection for measuring concentrations of serotonin in the dialysate. In this case the problem becomes the optimization of conditions to yield maximum signal for a given sample volume under the highest speed conditions with a certain required number of theoretical plates. It turns out that the observed concentration sensitivity at an electrochemical detector can be regulated by temperature, particle size, injection volume/column diameter, and void time. The theory was successfully used for optimization of neurotransmitter serotonin measurement by capillary HPLC when sampling from a microdialysis flow stream. The final conditions are: 150 μm i.d., 3.1cm long columns with 1.7 μm particle diameter working at a flow rate of 12 μL/min, an injection volume of 500 nL, and a temperature of 343 K. The retention time for serotonin is 22.7s, the analysis time is about 36 s (which allows for determination of 3-methoxytyramine), and the sampling time is about 0.8 min with a perfusion flow rate of 0.6 μL/min.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。