Extra-short humeral heads reduce glenohumeral joint overstuffing compared with short heads in anatomic total shoulder arthroplasty

在解剖型全肩关节置换术中,与短肱骨头相比,超短肱骨头可减少肩关节过度填充。

阅读:1

Abstract

BACKGROUND: Rotator cuff tears and glenoid loosening remain the two most common causes for revision after anatomic total shoulder arthroplasty. Oversizing of the humeral head leads to increased contact force across the glenohumeral joint and is hypothesized to contribute to clinical and radiographic failure. The purpose of this study is to compare the rate of radiographic overstuffing between standard short humeral heads and newer extra-short heads with decreased lateral offset. METHODS: Fifty-five consecutive anatomic total shoulder arthroplasties performed using extra-short humeral heads were retrospectively reviewed and compared with age- and sex-matched controls receiving standard short heads. A total of 110 postoperative radiographs were analyzed using the Iannotti's perfect circle method to compare the prosthesis' center of rotation (COR) with the native humeral head COR. A difference in the COR of >3.0 mm was considered malpositioned. Malpositioning medially was considered overstuffed, and malpositioning laterally was considered understuffed. The direction of displacement of malpositioned prostheses was categorized using a quadrant system. Furthermore, we used a novel method to evaluate medial and superior overstuffing by measuring the displacement between the anatomic and prosthetic head positions along perpendicular axes. RESULTS: Using the Iannotti's perfect circle method, 56% of heads were malpositioned. Overstuffing occurred more frequently with short heads compared with extra-short heads (47% vs. 4%, P < .001). Conversely, understuffing occurred more frequently with extra-short heads (47% vs. 15%, P = .001). Malpositioned extra-short heads were most frequently placed in the inferomedial quadrant (93% vs. 24%, P < .001), whereas malpositioned short heads were most commonly placed in the superomedial quadrant (56% vs. 7%, P < .001). Our novel measurement method demonstrated that extra-short heads reduced medial overstuffing (2.8 ± 2.8 mm vs. 0.3 ± 2.0 mm, P < .001). Both extra-short and short heads had similar rates of superior malpositioning (1.6 ± 2.2 mm vs. 1.4 ± 1.5 mm, P = .683). CONCLUSION: Routine use of extra-short humeral head sizes reduces the rate of medial glenohumeral joint overstuffing but not superior malpositioning. This is hypothesized to improve clinical outcomes, but future studies are needed to assess the relationship between improved humeral head fit and clinical outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。