Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial

一种新型术中工程化锐器伤预防装置的有效性:初步可用性和有效性试验

阅读:1

Abstract

BACKGROUND: The American College of Surgeons reports 88,320 intraoperative needlestick injuries (NSIs) per year, resulting in US $376 to US $2456 in costs per NSI. Engineered sharps injury prevention (ESIP) devices protect against NSIs. To our knowledge, no study has been published to date to demonstrate clinical effectiveness of an intraoperative ESIP device. Operative Armour is a wearable arm cuff that can be donned during surgical closure to allow surgeons to keep a suture pack and sharps protection container on their forearm. OBJECTIVE: We characterize Operative Armour's ESIP device effectiveness in a tertiary hospital, hypothesizing that this device will decrease NSI risk by decreasing behaviors associated with NSIs: needle passing and handling. METHODS: A prospective case-control study was conducted with institutional review board quality improvement designation in which authors observed skin closures of plastic surgery procedures. To ensure accuracy, one surgeon was observed at a time. Control surgeries were purely observational; intervention cases involved surgeon use of the device during skin closure. Outcomes of interest included needle passing, needle handling, lost needles, and loaded waiting needles. RESULTS: Surgeons were observed in 50 control and 50 intervention cases. Operative Armour eliminated needle passing during skin closure. One NSI occurred in one control case; no NSIs were observed in intervention cases (P=.36). The mean number of loaded and unprotected waiting needles was also significantly decreased in the intervention group from 2.3 to 0.2 (P<.001). Furthermore, a multivariable linear regression established that Operative Armour significantly decreased the number of needle adjustments by hand per stitch observed (F(4, 21.68)=3.72; P=.01). In fact, needle adjustments by hand decreased overall (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.004), and adjustments occurred half as frequently with use of Operative Armour in free flap reconstruction (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.03) and a quarter as frequently in other breast reconstruction cases such as mastopexy (1 adjustment per 20 stitches vs 1 adjustment per 5 stitches, P=.002). CONCLUSIONS: Operative Armour effectively functions as an ESIP device by decreasing intraoperative needle passing and handling. Although sample size prohibits demonstrating a decrease in NSIs during observed cases, by decreasing behaviors that drive NSI risk, we anticipate an associated decrease in NSIs with use of the device.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。