Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability

采用可调节环长皮质纽扣和高强度缝线加固的经骨隧道技术进行动态前路稳定,治疗复发性肩关节不稳

阅读:2

Abstract

Dynamic anterior stabilization using the long head of the biceps tendon is a recently described technique in the management of recurrent shoulder dislocation with subcritical bone loss. This technique involves the transfer of the long head of the biceps to the glenoid, providing sling and hammock effect. The long head of the biceps (LHB) tendon fixation can be accomplished with a variety of implants. We present a modified fixation technique of LHB tendon using transosseous bone tunnel with the adjustable loop length cortical button, incorporating high-strength suture augmentation device in a patient with recurrent glenohumeral instability with limited glenoid bone loss and an engaging Hill-Sachs defect in the humeral head.