Arthroscopic superior capsular reconstruction with dermal allograft for primary and recurrent rotator cuff tears

采用真皮异体移植进行关节镜下肩袖上囊重建术治疗原发性和复发性肩袖撕裂

阅读:2

Abstract

BACKGROUND: The aim of this study was to compare the clinical outcomes and retear rate of arthroscopic superior capsular reconstruction (SCR) with dermal allograft following structural failure of a previous rotator cuff repair, with a cohort of primary SCRs. METHODS: This was a retrospective comparative study with a study group comprising 22 patients who were followed up at a minimum of 24 (mean, 41; range, 27-65) months after SCR with dermal allograft performed for structural failure of a previous rotator cuff repair. The control group included 13 patients who previously underwent a primary SCR using dermal allograft and were followed up for 24 months. Clinical outcome measures comprised range of motion, the American Shoulder and Elbow Surgeons score, and the Western Ontario Rotator Cuff (WORC) Index. Radiological outcomes included the acromiohumeral interval and graft integrity on magnetic resonance imaging at one year. Logistic regression was used to determine whether SCR being undertaken as either a primary or revision procedure influenced functional outcomes or retear rate. RESULTS: The mean age at the time of surgery was 58 (range, 39-74) years for the study group and 60 (range, 48-70) years for the control group. Forward flexion improved from a mean of 117° (range, 7°-180°) preoperatively to 140° (range, 45°-170°) postoperatively (P = .11), and external rotation increased from a mean of 31° (range, 0°-70°) preoperatively to 36° (range, 0°-60°) postoperatively (P = .23). The American Shoulder and Elbow Surgeons score improved (P = 0) from a mean of 38 (range, 12-68) to 73 (range, 17-95), and the WORC Index improved (P = 0) from a mean of 29 (range, 7-58) to 59 (range, 30-97). Following SCR, there was no significant change in the acromiohumeral interval. The graft was intact in 42% of cases on magnetic resonance imaging and none of the retears underwent further surgery. Compared to revision SCR, primary SCR resulted in a significant improvement in forward flexion (P = .001), external rotation (P = 0), and WORC Index (P = .019). Logistic regression demonstrated that SCR performed as a revision procedure was associated with a higher retear rate (P = .006) and worse forward flexion (P = .009) and external rotation (P = .008). CONCLUSION: SCR using human dermal allograft following structural failure of a previous rotator cuff repair can lead to an improvement in clinical outcomes but the results are inferior to primary procedures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。