Determination of rotator cuff tear reparability: an ultrasound-based investigation

肩袖撕裂可修复性的判定:一项基于超声的研究

阅读:2

Abstract

BACKGROUND: The use of ultrasound as a viable diagnostic tool for routine office visit evaluation of rotator cuff integrity is slowly gaining acceptance in orthopedic practice. However, the reliability of accurately assessing rotator cuff tear reparability by ultrasound has limited evidence in the literature. The purpose of this study was to compare preoperative assessment of cuff tear reparability via ultrasound with the arthroscopic determination of reparability at the time of surgery. METHODS: We prospectively collected preoperative ultrasound and arthroscopic imaging data on 145 patients (80 or 55% men and average age of 60.7 years) who underwent arthroscopic posterior superior rotator cuff repair. Three independent experienced orthopedic surgeons retrospectively reviewed all ultrasound studies and arthroscopic imaging and determined if the posterior superior rotator cuff tendon edge was able to be viewed via ultrasound and determined with the arthroscopic images if the tear was reparable. RESULTS: On review of the ultrasound and arthroscopic data, if the edge of the rotator cuff tendon was able to be viewed on the coronal ultrasound image, it was most likely reparable with a positive predictive value of 97.6% and a positive likelihood ratio of 5.8. Sensitivity was 84.4%, and specificity was 76.9%. The negative predictive value was 37.5%, and the negative likelihood ratio was 0.17. The interobserver reliability was 0.63, and the observers were unanimous in determining the tendon edge was able to be visualized in 99 of 145 cases (68%). CONCLUSION: Preoperative ultrasound evaluation of the shoulder for posterior superior rotator cuff tears is a useful tool for assessing rotator cuff integrity and may help predict intraoperative reparability of the tendon. This study demonstrates that if the cuff tear edge is able to be visualized, there is a high probability of successful arthroscopic restoration of the tendon to its native attachment. Conversely, if the tear edge is unable to be visualized, there is a moderate chance of the tear being irreparable. These results help expand the knowledge base of the usefulness of in-office ultrasound performed by the surgeon in predicting the results of surgical intervention for rotator cuff tears.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。