Physiological in vitro sacroiliac joint motion: a study on three-dimensional posterior pelvic ring kinematics

体外生理性骶髂关节运动:三维后骨盆环运动学研究

阅读:2

Abstract

The sacroiliac joint (SIJ) is a well-known source of low back and pelvic pain, of increasing interest for both conservative and surgical treatment. Alterations in the kinematics of the pelvis have been hypothesized as a major cause of SIJ-related pain. However, definitions of both the range and the extent of physiological movement are controversial, and there are no clear baseline data for pathological alterations. The present study combined a novel biomechanical setup allowing for physiological motion of the lumbosacral transition and pelvis without restricting the SIJ movement in vitro, combined with optical image correlation. Six fresh human pelvises (81 ± 10 years, three females, three males) were tested, with bodyweight-adapted loading applied to the fifth lumbar vertebra and both acetabula. Deformation at the lumbopelvises was determined computationally from three-dimensional image correlation data. Sacroiliac joint motion under the loading of 100% bodyweight primarily consisted of a z-axis rotation (0.16°) and an inferior translation of the sacrum relative to the ilium (0.32 mm). Sacroiliac joint flexion-extension rotations were minute (< 0.02°). Corresponding movements of the SIJ were found at the lumbosacral transition, with an anterior translation of L5 relative to the sacrum of -0.97 mm and an inferior translation of 0.11 mm, respectively. Moreover, a flexion of 1.82° was observed at the lumbosacral transition. Within the innominate bone and at the pubic symphysis, small complementary rotations were seen around a vertical axis, accounting for -0.10° and 0.11°, respectively. Other motions were minute and accompanied by large interindividual variation. The present study provides evidence of different SIJ motions than reported previously when exerted by physiological loading. Sacroiliac joint kinematics were in the sub-degree and sub-millimeter range, in line with previous in vivo and in vitro findings, largely limited to the sagittal rotation and an inferior translation of the sacrum relative to the ilium. This given physiological loading scenario underlines the relevance of the lumbosacral transition when considering the overall motion of the lumbopelvis, and how relatively little the other segments contribute to overall motion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。