Saturation monitoring of VX15/2503, a novel semaphorin 4D-specific antibody, in clinical trials

在临床试验中对新型信号素4D特异性抗体VX15/2503进行饱和度监测

阅读:1

Abstract

BACKGROUND: Receptor occupancy, or saturation, assays are often utilized in preclinical and clinical development programs to evaluate the binding of a biologic to a cellular target. These assays provide critical information regarding the dose of drug required to "saturate" the target as well as important pharmacodymamic (PD) data. A flow cytometric method was developed to measure the degree of Semaphorin 4D (SEMA4D; CD100) saturation by VX15/2303, an investigational monoclonal antibody specific for SEMA4D. METHODS: The assay detects VX15/2503, a human IgG4 specific for SEMA4D, with an IgG4 -specific monoclonal antibody. RESULTS: Data generated allowed assessment of two related SEMA4D-specific pharmacodynamic (PD) markers: (1) The measurement of cellular SEMA4D (cSEMA4D) saturation by VX15/2503, and (2) the cell membrane expression levels of cSEMA4D. CONCLUSIONS: This assay specifically and reproducibly measured cSEMA4D saturation and expression levels. Evaluation of the SEMA4D-specific PD markers were critical in determining the clinical saturation threshold of cSEMA4D by VX15/2503.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。