Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)

使用光学相干断层扫描辅助经皮冠状动脉介入治疗的患者中,新一代软件(Ultreon™ 1.0 软件)与老一代软件(AptiVue™ 软件)在手术相关差异和临床结果方面的比较

阅读:1

Abstract

(1) Introduction: Optical coherence tomography (OCT) intravascular imaging facilitates percutaneous coronary intervention (PCI). Software for OCT is being constantly improved, including the latest version Ultreon™ 1.0 Software (U) (Abbott Vascular, Santa Clara, CA, USA). In the current analysis, we aim to compare processing results, procedural indices as well as clinical outcomes in patients treated via PCI. This was conducted using earlier generation OCT imaging software versions (non-U) and the newest available one on the market (U). (2) Methods: The study comprised 95 subsequent and not selected patients (55 processed with U and 40 non-U). The non-U processings were transferred for evaluation by U software, while the comparison of OCT parameters, selected clinical and procedural indices was performed between groups. We further assessed clinical outcomes during the follow-up period, i.e., major adverse cardiovascular events (MACE) and predictors of stent expansion. (3) Results: We did not detect any differences in general features between either of the assessed groups at baseline. Non-U software was more often used for bare-metal stenting (p = 0.004), while PCIs in the U group demanded a greater number of stents (p = 0.03). The distal reference of external elastic lamina (EEL) diameter was greater in the non-U group (p = 0.02) with no concurrent differences in minimal (p = 0.27) and maximal (p = 0.31) stent diameter. It was also observed that MACE was more frequently observed in the non-U group (p = 0.01). Neither univariable (estimate: 0.407, 95%CI: (-3.182) - 3.998, p = 0.82) nor multivariable (estimate: 2.29, 95%CI: (-4.207) - 8.788, p = 0.5) analyses demonstrated a relationship between the type of software and stent expansion. (4) Conclusions: Improvement in the software for image acquisition and processing of OCT is not related to stent expansion. The EEL diameter is preferably used to select the distal stent diameter in newer software.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。