Preclinical evaluation of thin convex probe endobronchial ultrasound-guided transbronchial needle aspiration for intrapulmonary lesions

细凸探头支气管内超声引导下经支气管针吸活检对肺内病变的临床前评估

阅读:10
作者:Tsukasa Ishiwata, Terunaga Inage, Alexander Gregor, Yamato Motooka, Harley H L Chan, Nicholas Bernards, Masato Aragaki, Zhenchian Chen, Hideki Ujiie, Tomonari Kinoshita, Andrew Effat, Kazuhiro Yasufuku

Background

Conventional flexible bronchoscopy has not achieved the high diagnostic yield for intrapulmonary lesions as seen with image-guided transthoracic biopsy. A thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) with a 5.9-mm tip was designed to improve peripheral access over conventional EBUS bronchoscopes to facilitate real-time sampling of intrapulmonary lesions under ultrasound guidance.

Conclusions

TCP-EBUS has the potential to facilitate safe real-time transbronchial sampling of intrapulmonary lesions in the central and middle lung fields.

Methods

TCP-EBUS was inserted into the distal airways of ex-vivo human lungs to assess bronchial accessibility relative to clinically available bronchoscopes. The short- (≤1 h) and medium-term (≤10 d) safety of TCP-EBUS insertion and EBUS-guided transbronchial needle aspiration (TBNA) using a 25-gauge needle were evaluated physiologically and radiologically in live pigs. TCP-EBUS-guided TBNA feasibility was assessed in-vivo with pig intrapulmonary pseudo-tumors and ex-vivo with resected human lung cancer specimens.

Results

For bronchial accessibility, TCP-EBUS demonstrated greater reach than the 6.6-mm convex probe endobronchial ultrasound (CP-EBUS) in all bronchi, as well as surpassed a 5.5-mm conventional bronchoscope in 63% (131/209) and a 4.8-mm conventional bronchoscope in 27% (57/209) of assessed bronchi. The median bronchial generation and the mean diameter of bronchi TCP-EBUS reached was 4 (range, 3-7) and 3.3±0.7 mm, respectively. No major complications related to TCP-EBUS-guided TBNA in distal airways were observed in the live pigs. Scattered mucosal erythema of the bronchial walls was observed immediately after TCP-EBUS insertion; this self-resolved by day 10. TCP-EBUS could successfully reach and visualize intrapulmonary targets via ultrasound, with no difficulty in needle deployment or sampling. Conclusions: TCP-EBUS has the potential to facilitate safe real-time transbronchial sampling of intrapulmonary lesions in the central and middle lung fields.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。