Radiolucent cerclage for humerus fractures: beware of radial nerve injury-a case report

肱骨骨折的透射线环扎术:警惕桡神经损伤——病例报告

阅读:2

Abstract

A 73-year-old woman was referred to a National Centre for Peripheral Nerve Injury with a post-operative left radial nerve degenerative lesion following open reduction and internal fixation of a proximal third humerus fracture using radiolucent Arthrex FiberTape® Cerclage as an adjunct to plating to improve stability. Intra-operative photographs illustrate compression of the radial nerve under the cerclage construct. Use of radiolucent cerclage for humerus fractures is increasing with modern systems capable of withstanding an ultimate load of 4300 N. We highlight the risk of debilitating neurological injury when not deployed safely and describe anatomical high-risk zones for injury. We emphasize the impact of delay in diagnosis and treatment.