Linearly polarized excitation enhances signals from fluorescent voltage indicators

线性偏振激发可增强荧光电压指示剂的信号。

阅读:2

Abstract

Voltage imaging in cells requires high-speed recording of small fluorescent signals, often leading to low signal/noise ratios. Because voltage indicators are membrane bound, their orientations are partially constrained by the plane of the membrane. We explored whether tuning the linear polarization of excitation light could enhance voltage indicator fluorescence. We tested a panel of dye- and protein-based voltage indicators in mammalian cells. The dye BeRST1 showed a 73% increase in brightness between the least and most favorable polarizations. The protein-based reporter ASAP1 showed a 22% increase in brightness, and QuasAr3 showed a 14% increase in brightness. In very thin neurites expressing QuasAr3, improvements were anomalously large, with a 170% increase in brightness between polarization parallel versus perpendicular to the dendrite. Signal/noise ratios of optically recorded action potentials were increased by up to 50% in neurites expressing QuasAr3. These results demonstrate that polarization control can be a facile means to enhance signals from fluorescent voltage indicators, particularly in thin neurites or in high-background environments.