A comparison of calcium-activated potassium channel currents in cell-attached and excised patches

比较细胞贴附式膜片和膜片切除式膜片中钙激活钾通道电流。

阅读:1

Abstract

Single channel currents from Ca-activated K channels were recorded from cell-attached patches, which were then excised from 1321N1 human astrocytoma cells. Cells were depolarized with K (110 mM) so that the membrane potential was known in both patch configurations, and the Ca ionophore A23187 or ionomycin (20-100 microM) was used to equilibrate intracellular and extracellular [Ca] (0.3 or 1 microM). Measurements of intracellular [Ca] with the fluorescent Ca indicator quin2 verified that [Ca] equilibration apparently occurred in our experiments. Under these conditions, where both membrane potential and intracellular [Ca] were known, we found that the dependence of the channel percent open time on membrane potential and [Ca] was similar in both the cell-attached and excised patch configuration for several minutes after excision. Current-voltage relations were also similar, and autocorrelation functions constructed from the single channel currents revealed no obvious change in channel gating upon patch excision. These findings suggest that the results of studies that use excised membrane patches can be extrapolated to the K-depolarized cell-attached configuration, and that the relation between [Ca] and channel activity can be used to obtain a quantitative measure of [Ca] near the membrane intracellular surface.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。