Beclin1 circulating level as predictor of carotid intima-media thickness in patients with type 2 diabetes mellitus

Beclin1 循环水平作为 2 型糖尿病患者颈动脉内膜中层厚度的预测指标

阅读:4
作者:Mervat Naguib, Aya Tarabay, Nashwa ElSaraf, Lila Rashed, Amr ElMeligy

Abstract

Type 2 diabetes (T2DM) represents a major risk factor for atherosclerosis that is the underlying cause of most cardiovascular diseases. Identifying reliable predictive biomarkers are needed to improve the long-term outcome in diabetic patients. Autophagy plays a pivotal role in the pathogenesis of atherosclerosis. Beclin1 is a key regulatory protein of autophagy and has been localized in human atherosclerotic lesions. However, the relation of serum level of Beclin1 and atherosclerosis in patients with diabetes has not been clarified yet.To assess the relationship between serum level of Beclin1 and carotid intima-media thickness (CIMT) in patients with T2DM.In this case-control study participants were recruited from tertiary care hospitals in Egypt. The study enrolled 50 patients with T2DM and 25 healthy subjects between January, 2019 and January, 2020. Age, gender, and body mass index were recorded for all subjects. Laboratory works up including glycated hemoglobin, lipid panel, and serum Beclin1 (by enzyme-linked immunosorbent assay) were measured. CIMT was assessed by color Doppler. Comparisons between patients and the control group were done using analysis of variance and Chi-square test. Correlations between CIMT and Beclin1 level and different variables were done using the Pearson correlation coefficient. Receiver operator characteristic curve was constructed with the area under curve analysis performed to detect the best cutoff value of Beclin1 for detection of CIMT > 0.05 cm.The level of Beclin1 in the patient group was significantly lower compared with that in the control group (1.28 ± 0.51 vs 5.24 ± 1.22 ng/dL, P < .001). The level of Beclin1 apparently decreased in the higher CIMT group in T2DM patients. Serum Beclin1 levels were negatively correlated with CIMT (r = -0.762; P < .001), low-density lipoprotein-cholesterol (r = -0.283; P = .04), and triglycerides (r = -0.350; P = .01) but positively correlated with high-density lipoprotein-cholesterol (r = 0.491; P < .001) in patients with T2DM. Beclin1 level >2.2 ng/dL was an accurate predictor of CIMT >0.05 cm with an area under the curve value of 0.997, 93.9% sensitivity, and 100% specificity.Beclin1 levels were negatively correlated with atherosclerotic load in patients with T2DM and it may be considered as a promising diagnostic and therapeutic target.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。