Tracheal swab from front of neck airway for SARS-CoV-2; a bronchial foreign body

颈前气道气管拭子检测SARS-CoV-2;支气管异物

阅读:1

Abstract

We report the case of a bronchial foreign body, following a tracheostomy site swab for SARS-CoV-2, aiming to raise awareness and vigilance. A qualified nurse was performing a routine SARS-CoV-2 swab on a 51-year-old woman, fitted with a tracheostomy in the recent past following a craniotomy. This was part of the discharging protocol to a nursing home. During the sampling, part of the swab stylet snapped and was inadvertently dropped through the tracheostomy site. Initial CT imaging was reported as showing no signs of a foreign body but some inflammatory changes. Bedside flexible endoscopy through the tracheostomy site revealed the swab in a right lobar bronchus. This was subsequently removed by flexible bronchoscopy. This case highlights the need for clear guidance on how samples for SARS-CoV-2 are taken from patients with front of neck airways (laryngectomy/tracheοstomy) and the potential pitfalls involved.