Novel custom made composite spacer for first-stage revision total hip replacement in the presence of extensive acetabular/femoral bone loss with abductor deficiency

一种新型定制复合材料垫片,适用于伴有广泛髋臼/股骨骨缺损和外展肌功能不全的一期翻修全髋关节置换术。

阅读:2

Abstract

A two-stage revision total hip replacement (THR) remains the gold standard for treating chronic periprosthetic joint infection. The goals for the first stage are twofold: (1) remove infected tissue/implants, obtaining tissue samples for culture; (2) deliver local antibiotics and maintain hip function with a prosthesis with antibiotic-loaded acrylic cement. With extensive bone loss prefabricated spacers are not sufficient, therefore customised spacers are required. The current technique, coating cephalomedually femoral nail in cement, is complex, time consuming, functions poorly and causes wear debris from excessive friction at the femoral/acetabular articulation. We report a technique to create a custom made composite spacer using a short femoral nail, standard Exeter femoral stem (Stryker), Trident acetabular cup (Stryker) and polymethyl methacrylate (PMMA) bone cement with antibiotics. This technique restores hip biomechanics and gives a stable articulation, even in the presence of abductor deficiency, due to dual mobility bearings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。