Biomechanical analysis of a double fixation method for tendon graft in porcine tibia - using an interference screw plus staple

采用干涉螺钉加钉固定法对猪胫骨肌腱移植进行双重固定的生物力学分析。

阅读:1

Abstract

OBJECTIVE: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. METHODS: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F(10)), yield load (F(y)), and stiffness. RESULTS: The mean values of graft cross-sectional area, F(10), F(y), and stiffness did not present significant differences between the groups. CONCLUSION: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。