Sonographic twinkling artifact for diagnosis of acute ureteral calculus

超声闪烁伪影在急性输尿管结石诊断中的应用

阅读:2

Abstract

OBJECTIVE: We compared the performance of color Doppler twinkling artifacts with B-ultrasound and computed tomography (CT) for diagnosis of ureteral calculus in patients with acute renal colic. METHODS: The location and size of ureteral stones in 2268 patients with acute renal colic were determined using the two ultrasound methods and CT. All cases were followed up for 2-8 weeks. RESULTS: Color Doppler twinkling artifacts had a sensitivity of 96.98%, specificity of 90.39%, positive predictive value (PPV) of 99.77%, and negative predictive value (NPV) of 41.23%. B-Ultrasound had a sensitivity of 96.39%, specificity of 80.77%, PPV of 99.53%, and NPV of 34.43%. CT had a sensitivity of 99.59%, specificity of 94.23%, PPV of 99.86%, and NPV of 84.48%. The area under the receiver operating characteristic curve was 0.925 for color Doppler twinkling artifacts, 0.863 for B-ultrasound, and 0.963 for CT. CONCLUSION: For the diagnosis of ureteral calculus, the sonographic twinkling artifact had a similar performance as CT. We suggest use of the sonographic twinkling artifact instead of CT for patients with acute renal colic to reduce the examination time and exposure to radiation, and to provide earlier access to treatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。