Characteristics of physical blocking on co-occupant's exposure to respiratory droplet residuals

物理阻隔对同住者呼吸道飞沫残留暴露的影响特征

阅读:2

Abstract

Existed evidences show that airborne transmission of human respiratory droplets may be related with the spread of some infectious disease, such as severe acute respiratory syndrome (SARS) and H1N1 pandemic. Non-pharmaceutical approaches, including ventilation system and personal protection, are believed to have certain positive effects on the reduction of co-occupant's inhalation. This work then aims to numerically study the performances of mouth covering on co-occupant's exposure under mixing ventilation (MV), under-floor air distribution (UFAD) and displacement ventilation (DV) system, using drift-flux model. Desk partition, as one generally employed arrangement in plan office, is also investigated under MV. The dispersion of 1, 5 and 10 μm droplet residuals are numerically calculated and CO(2) is used to represent tracer gas. The results show that using mouth covering by the infected person can reduce the co-occupant's inhalation greatly by interrupting direct spread of the expelled droplets, and best performance can be achieved under DV since the coughed air is mainly confined in the microenvironment of the infected person. The researches under MV show that the two interventions, mouth covering and desk partition, achieve almost the same inhalation for fine droplets while the inhalation of the co-occupant is lower when using mouth covering for large droplets.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。