Echocardiographic Linear Dimensions for Assessment of Right Ventricular Chamber Volume as Demonstrated by Cardiac Magnetic Resonance

心脏磁共振成像显示,超声心动图线性尺寸可用于评估右心室腔容积

阅读:1

Abstract

BACKGROUND: Echocardiography-derived linear dimensions offer straightforward indices of right ventricular (RV) structure but have not been systematically compared with RV volumes on cardiac magnetic resonance (CMR). METHODS: Echocardiography and CMR were interpreted among patients with coronary artery disease imaged via prospective (90%) and retrospective (10%) registries. For echocardiography, American Society of Echocardiography-recommended RV dimensions were measured in apical four-chamber (basal RV width, mid RV width, and RV length), parasternal long-axis (proximal RV outflow tract [RVOT]), and short-axis (distal RVOT) views. For CMR, RV end-diastolic volume and RV end-systolic volume were quantified using border planimetry. RESULTS: Two hundred seventy-two patients underwent echocardiography and CMR within a narrow interval (0.4 ± 1.0 days); complete acquisition of all American Society of Echocardiography-recommended dimensions was feasible in 98%. All echocardiographic dimensions differed between patients with and those without RV dilation on CMR (P < .05). Basal RV width (r = 0.70), proximal RVOT width (r = 0.68), and RV length (r = 0.61) yielded the highest correlations with RV end-diastolic volume on CMR; end-systolic dimensions yielded similar correlations (r = 0.68, r = 0.66, and r = 0.65, respectively). In multivariate regression, basal RV width (regression coefficient = 1.96 per mm; 95% CI, 1.22-2.70; P < .001), RV length (regression coefficient = 0.97; 95% CI, 0.56-1.37; P < .001), and proximal RVOT width (regression coefficient = 2.62; 95% CI, 1.79-3.44; P < .001) were independently associated with CMR RV end-diastolic volume (r = 0.80). RV end-systolic volume was similarly associated with echocardiographic dimensions (basal RV width: 1.59 per mm [95% CI, 1.06-2.13], P < .001; RV length: 1.00 [95% CI, 0.66-1.34], P < .001; proximal RVOT width: 1.80 [95% CI, 1.22-2.39], P < .001) (r = 0.79). CONCLUSIONS: RV linear dimensions provide readily obtainable markers of RV chamber size. Proximal RVOT and basal width are independently associated with CMR volumes, supporting the use of multiple linear dimensions when assessing RV size on echocardiography.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。