A mosquito feeding assay to examine Plasmodium transmission to mosquitoes using small blood volumes in 3D printed nano-feeders

使用 3D 打印纳米喂食器中的少量血液进行蚊子进食试验,以检查疟原虫向蚊子的传播情况

阅读:11
作者:Wouter Graumans, Roel Heutink, Geert-Jan van Gemert, Marga van de Vegte-Bolmer, Teun Bousema, Katharine A Collins

Background

To understand the dynamics of malaria transmission, membrane feeding assays with glass feeders are used to assess the transmission potential of malaria infected individuals to mosquitoes. However, in some circumstances, use of these assays is hindered by both the blood volume requirement and the availability of fragile, specially crafted glass feeders. 3D printed plastic feeders that require very small volumes of blood would thus expand the utility of membrane feeding assays.

Conclusions

Here we present 3D printed mini- and nano-feeders with comparable performance to the currently used glass mini-feeders. These feeders do not require specialized glass craftsmanship, making them easily accessible. Moreover, the smaller nano-feeders will enable evaluation of smaller blood volumes that can be collected from finger prick, thus expanding the utility of membrane feeding assays and facilitating a more thorough evaluation of the human infectious reservoir for malaria.

Methods

Using two 3D printing production methods, MultiJet (MJ) and Digital Light Processing (DLP), we developed a plastic version of the most commonly used standard glass feeder (the mini-feeder) with an improved design, and also a smaller feeder requiring only 60 µl of blood (the nano-feeder). Performance of the 3D printed feeders was compared to standard glass mini-feeders by assessing infectivity of gametocytes to mosquitoes in standard membrane feeding assays with laboratory reared Anopheles stephensi mosquitoes and cultured Plasmodium falciparum gametocytes. In addition, the optimum number of mosquitoes that can feed on the nano-feeder was determined by evaluating fully fed mosquitoes visually and by assessing blood- meal volume with a colorimetric haemoglobin assay.

Results

The 3D printing methods allowed quick and inexpensive production of durable feeders. Infectivity of gametocytes to mosquitoes was comparable for MJ and DLP 3D printed feeders and glass feeders, and the performance of the 3D printed feeders was not influenced by repeated washing with bleach. There was no loss in transmission efficiency when the feeder size was reduced from mini-feeder to nano-feeder, and blood-meal volume assessment indicated ~10 An. stephensi mosquitoes can take a full blood-meal (median volume 3.44 µl) on a nano-feeder. Conclusions: Here we present 3D printed mini- and nano-feeders with comparable performance to the currently used glass mini-feeders. These feeders do not require specialized glass craftsmanship, making them easily accessible. Moreover, the smaller nano-feeders will enable evaluation of smaller blood volumes that can be collected from finger prick, thus expanding the utility of membrane feeding assays and facilitating a more thorough evaluation of the human infectious reservoir for malaria.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。