Fluorescence-based method is more accurate than counting-based methods for plotting growth curves of adherent cells

对于绘制贴壁细胞的生长曲线,基于荧光的方法比基于计数的方法更准确。

阅读:1

Abstract

OBJECTIVE: Cell growth curves constitute one of the primary assays employed to analyze cell proliferation dynamics of in vitro cultured cells under specific culture conditions. From the cell growth curve, it is possible to assess the behavior of proliferating cells under different conditions, such as drug treatment and genomic editions. Traditionally, growth curves for adherent cells are obtained by seeding the cells in multiple-well plates and counting the total number of cells at different time points. Here, we compare this traditional method to the fluorescence-based method, which is based on the CFSE fluorescence decay over time. RESULTS: The fluorescence-based method is not dependent on the determination of the total number of cells, but rather is approached by assessing the fluorescence of a sample of single cells from a cell population at different time points after plating. Therefore, this method is not biased due to either cell loss during harvesting or to the presence of cellular debris and cell clumps. Moreover, the fluorescence-based method displays lower variation among different measurements of the same time point, which increases the reliability on the determination of lag, log and stationary phase transitions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。