Sensitivity and specificity of multiple Kato-Katz thick smears and a circulating cathodic antigen test for Schistosoma mansoni diagnosis pre- and post-repeated-praziquantel treatment

多次 Kato-Katz 厚涂片检查和循环阴极抗原检测在重复吡喹酮治疗前后诊断曼氏血吸虫病的敏感性和特异性

阅读:2

Abstract

BACKGROUND: Two Kato-Katz thick smears (Kato-Katzs) from a single stool are currently recommended for diagnosing Schistosoma mansoni infections to map areas for intervention. This 'gold standard' has low sensitivity at low infection intensities. The urine point-of-care circulating cathodic antigen test (POC-CCA) is potentially more sensitive but how accurately they detect S. mansoni after repeated praziquantel treatments, their suitability for measuring drug efficacy and their correlation with egg counts remain to be fully understood. We compared the accuracies of one to six Kato-Katzs and one POC-CCA for the diagnosis of S. mansoni in primary-school children who have received zero to ten praziquantel treatments. We determined the impact each diagnostic approach may have on monitoring and evaluation (M&E) and drug-efficacy findings. METHOD/PRINCIPLE FINDINGS: In a high S. mansoni endemic area of Uganda, three days of consecutive stool samples were collected from primary school-aged children (six - 12 years) at five time-points in year one: baseline, one-week-post-, four-weeks-post-, six-months-post-, and six-months-one-week-post-praziquantel and three time-points in years two and three: pre-, one-week-post- and four-weeks-post-praziquantel-treatment/retreatment (n = 1065). Two Kato-Katzs were performed on each stool. In parallel, one urine sample was collected and a single POC-CCA evaluated per child at each time-point in year one (n = 367). At baseline, diagnosis by two Kato-Katzs (sensitivity = 98.6%) or one POC-CCA (sensitivity = 91.7%, specificity = 75.0%) accurately predicted S. mansoni infections. However, one year later, a minimum of three Kato-Katzs, and two years later, five Kato-Katzs were required for accurate diagnosis (sensitivity >90%) and drug-efficacy evaluation. The POC-CCA was as sensitive as six Kato-Katzs four-weeks-post and six-months-post-treatment, if trace readings were classified as positive. CONCLUSIONS/SIGNIFICANCE: Six Kato-Katzs (two/stool from three stools) and/or one POC-CCA are required for M&E or drug-efficacy studies. Although unable to measure egg reduction rates, one POC-CCA appears to be more sensitive than six Kato-Katzs at four-weeks-post-praziquantel (drug efficacy) and six-months-post-praziquantel (M&E).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。