Use of daily electronic patient-reported outcome (PRO) diaries in randomized controlled trials for rheumatoid arthritis: rationale and implementation

在类风湿性关节炎随机对照试验中使用每日电子患者报告结局(PRO)日记:原理和实施

阅读:2

Abstract

BACKGROUND: Rheumatoid arthritis (RA) is associated with significantly diminished health-related quality of life. Patient-reported outcomes (PROs) are considered important in RA; however, some symptoms such as morning joint stiffness (MJS) and fatigue that are considered important by patients are not captured by the American College of Rheumatology "core set" measures for RA trials. The US Food and Drug Administration has endorsed electronic capture of clinical trial data including PROs, and electronic PRO (ePRO) systems may lead to more accurate and complete data capture, improved compliance, and patient acceptance compared with paper-based methods. Our objective was to assess the implementation of ePRO measures of Duration and Severity of MJS, Severity of Worst Tiredness, and Severity of Worst Joint Pain in baricitinib RA-BEAM and RA-BUILD phase 3 randomized clinical trials (RCTs). METHODS: A daily electronic diary (handheld device; Invivodata®, Inc.) was utilized to capture PRO data in the RCTs. Three "reporting window" options were incorporated to accommodate differences in patients' routine daily schedules, and alarms were programmed for each reporting window. Duration of MJS was recorded in "hours and minutes," and Severity of MJS, Worst Tiredness, and Worst Joint Pain were captured on a 0 to 10 rating scale, with a higher score indicating more severe symptoms. The patients and site staff were trained to use the daily electronic diary. RESULTS: Patients with moderately to severely active RA used the daily electronic diary in the RA-BEAM study (N = 1305) and RA-BUILD study (N = 684). The average compliance, calculated as total days completed by patients compared with total days expected to complete the diary, through Week 12 was high (RA-BEAM 94% patients; RA-BUILD 93% patients), potentially attributable to appropriate training, clarity of instructions, simple user interface, and electronic device design. Identified process challenges included non-timely issuance of the device, low battery, inadequate training of patients before data collection, inappropriate diary set-up, and first response entry 1 day after the baseline visit. CONCLUSIONS: High compliance rates support the use of the daily electronic PRO diary in large RCTs. Despite the anticipated issues, the daily electronic diary is expected to reduce recall bias and improve the quality of PRO data collection. TRIAL REGISTRATION: RA-BEAM ( NCT01710358 ) and RA-BUILD ( NCT01721057 ).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。