Prospective trial of the detection of urolithiasis on ultralow dose (sub mSv) noncontrast computerized tomography: direct comparison against routine low dose reference standard

超低剂量(亚毫西弗)非增强计算机断层扫描检测泌尿系结石的前瞻性试验:与常规低剂量参考标准的直接比较

阅读:2

Abstract

PURPOSE: In this prospective trial we compared ultralow dose computerized tomography reconstruction algorithms and routine low dose computerized tomography for detecting urolithiasis. MATERIALS AND METHODS: A total of 48 consenting adults prospectively underwent routine low dose noncontrast computerized tomography immediately followed by an ultralow dose series targeted at a 70% to 90% reduction from the routine low dose technique (sub mSv range). Ultralow dose series were reconstructed with filtered back projection, and adaptive statistical and model based iterative reconstruction techniques. Transverse (axial) and coronal images were sequentially reviewed by 3 relatively inexperienced trainees, including a radiology resident, a urology fellow and an abdominal imaging fellow. Three experienced abdominal radiologists independently reviewed the routine low dose filtered back projection images, which served as the reference standard. RESULTS: The mean effective dose for the ultralow dose scans was 0.91 mSv (median 0.82), representing a mean ± SD 78% ± 5% decrease compared to the routine low dose. Overall sensitivity and positive predictive value per stone for ultralow dose computerized tomography at a 4 mm threshold was 0.91 and 0.98, respectively. Sensitivity, specificity, positive and negative predictive values, and accuracy per patient were 0.87, 1.00, 1.00, 0.94 and 0.96, respectively. At a 4 mm threshold the sensitivity and positive predictive value per stone of the ultralow dose series for filtered back projection, and adaptive statistical and model based iterative reconstruction was 0.89 and 0.96, 0.91 and 0.98, and 0.93 and 1.00, respectively. Sensitivity, specificity, positive and negative predictive values, and accuracy per patient at the 4 mm threshold were 0.82, 1.00, 1.00, 0.91 and 0.94 for filtered back projection, 0.85, 1.00, 1.00, 0.93 and 0.95 for adaptive statistical iterative reconstruction, and 0.94, 1.00, 1.00, 0.97 and 0.98 for model based iterative reconstruction, respectively. Sequential review of coronal images changed the final stone reading in 13% of cases and improved diagnostic confidence in 49%. CONCLUSIONS: At a 4 mm renal calculus size threshold ultralow dose computerized tomography is accurate for detection when referenced against routine low dose series with dose reduction to below the level of a typical 2-view plain x-ray of the kidneys, ureters and bladder. Slight differences were seen among the reconstruction algorithms. There was mild improvement with model based iterative reconstruction over filtered back projection and adaptive statistical iterative reconstruction. Coronal images improved detection and diagnostic confidence over axial images alone.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。