Reproducibility and Screening Capability of Corneal Epithelial Thickness Measurement for Keratoconus Using Anterior Segment Optical Coherence Tomography

利用前节光学相干断层扫描技术测量圆锥角膜角膜上皮厚度的可重复性和筛查能力

阅读:1

Abstract

PURPOSE: To investigate the reproducibility of corneal epithelial thickness measurements using anterior segment optical coherence tomography (AS-OCT, CASIA2, TOMEY) and evaluate its potential for the diagnosis of keratoconus. PATIENTS AND METHODS: This study included patients diagnosed with stage 1-2 keratoconus (Amsler-Krumeich classification) at the Nagoya Eye Clinic and healthy controls. Corneal epithelial thickness was measured with the CASIA2 AS-OCT. Sixteen patients with keratoconus (16 eyes) and 11 healthy controls (11 eyes) underwent three consecutive measurements to determine the intraclass correlation coefficient (ICC). Measurements were taken for eight corneal sections in 40 keratoconus eyes (mean age: 25.5 ± 8.0 years) and 44 normal eyes (mean age: 24.2 ± 5.1 years). The mean corneal epithelial thickness, the upper-to-lower corneal epithelial thickness ratio, and the standard deviation of thickness across segments were compared between the two groups. Logistic regression analysis was used to evaluate corneal epithelial thickness-related parameters for the diagnosis of keratoconus. The cutoff value was determined using the Youden index derived from the receiver operating characteristic (ROC) curve. RESULTS: The ICC was ≥0.95 in all areas for both keratoconus and normal eyes. The superior paracentral corneal epithelium was significantly thicker in the keratoconus eyes, whereas the inferior paracentral area was thinner compared to normal eyes (p<0.001). The standard deviation of corneal epithelial thickness was significantly higher in keratoconus eyes across all regions. Logistic regression analysis identified the standard deviation of corneal epithelial thickness (2-5 mm) and the mean thickness ratio (0-5 mm) as explanatory variables. The area under the ROC curve was 0.955, with sensitivity and specificity of 92.1% and 100%, respectively. CONCLUSION: Corneal epithelial thickness measurements using the AS-OCT CASIA2 were highly reproducible and showed significant differences between early-stage keratoconus and normal corneas. These findings suggest its potential utility as a screening tool for keratoconus.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。