Comparison of Online Visual Acuity Testing with Dynamic Dyop and Static LogMAR Optotypes in Healthy Non-Presbyopic and Presbyopic Individuals

健康非老视者和老视者在线视力测试中动态Dyop和静态LogMAR视标的比较

阅读:2

Abstract

INTRODUCTION: Visual acuity (VA) is typically measured using stationary optotypes, though real-world visual experiences involve dynamic targets. The Dyop (dynamic optotype) VA test is a computerized motion perception assessment designed to simulate daily visual experiences. With the rise of telemedicine, this study examined the feasibility and agreement between virtual online VA testing using Dyop compared to standard LogMAR optotypes in non-presbyopic and presbyopic participants. METHODS: After an initial online Zoom(®) meeting verifying inclusion criteria and technical feasibility, participants accessed the examiner's computer using the "Anydesk" application enabling them to view the "Chart 2020" program. Monocular right eye VA was measured three consecutive times using Dyop and LogMAR optotypes in a counter-balanced design. Participants aged 18-39 yrs were considered non-presbyopic, and those 40-60 yrs were considered presbyopic. VA measurements were analyzed using the Mann-Whitney U-test, Spearman correlation coefficients, intraclass correlation coefficients (ICC), and non-parametric Bland-Altman analysis, which examined median differences and limits of agreement (LoA). RESULTS: Of the 110 participants, (70% females, mean age: 32.5 ± 13.0, range: 18-60), 73 (66%) were considered non-presbyopic (mean age: 24.1 ± 4.9, range: 18-39), and 37 (34%) were presbyopic (mean age: 49.0 ± 6.4, range: 40-60). The mean VA measured with the Dyop and LogMAR charts for the entire cohort (0.09 and 0.08), for the non-presbyopic (0.09 and 0.07) and the presbyopic (0.10 and 0.09) sub-groups was significantly positively correlated (r = 0.80, p < 0.001, r = 0.82, p < 0.001 and r = 0.72, p < 0.001, respectively), with a small mean difference (-0.01 ± 0.08, -0.02 ± 0.08, -0.01 ± 0.09 log units), for the entire cohort, the non-presbyopic, and the presbyopic, respectively. There were no significant differences between the two tests for the whole cohort (p = 0.80), for group 1 (p = 0.98) and for group 2 (p = 0.62). CONCLUSION: This study demonstrated the feasibility of online VA measurements and that online VA measurements using Dyop and LogMAR optotypes are interchangeable in healthy non-presbyopic and presbyopic participants.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。