Retrospective Comparison of Intraoperative Parameters, Efficacy and Safety in Cataract Surgery Between Halogen and Light-Emitting Diode (LED) Illuminated Surgical Microscope

回顾性比较卤素灯和发光二极管(LED)照明手术显微镜在白内障手术中的术中参数、疗效和安全性

阅读:1

Abstract

PURPOSE: The objective was to compare the operative time, ultrasound time, efficacy and safety of phacoemulsification with IOL insertion between using halogen and light-emitting diode (LED) illuminated microscope. PATIENTS AND METHODS: Two hundred and twenty-seven surgical charts of cataract patients who underwent phacoemulsification with IOL insertion between June 2018 and October 2020 were reviewed. There were 113 cases operated on under halogen-illuminated microscope (Carl Zeiss OPMI LUMERA S7(®)) and 114 cases operated on under light-emitting diode (LED)-illuminated microscope (Leica PROVEO 8(®)). All cases were operated on by the same surgeon (S.T.). The difference in operative time and ultrasound time between two groups was compared by independent samples t-test. The proportion of cases with 3-months BCVA that was better than 20/30 and the proportion of cases with intraoperative complications from the operation between two groups were compared by Pearson's Chi-squared test. RESULTS: The mean ultrasound time was 121.29±53.60 seconds in halogen group and 123.98±61.53 seconds in LED group. The mean difference was -2.69±8.44 seconds which was not statistically significant (95% CI, -19.35 to 13.97; p=0.573). The mean operative time was 19.83±4.77 minutes in the halogen group and 17.20±3.02 minutes in the LED group. The mean difference was 2.63±0.53 minutes (95% CI, 1.59 to 3.67; p < 0.001). The cases with BCVA better than 20/30 was 93.69% in halogen group and 95.49% in LED group. The proportion of cases with intraoperative complications was 3.53% in halogen group and 2.63% in LED group. The difference of both proportions was not statistically significant (p=0.553 and p=0.692, respectively). CONCLUSION: This study shows statistically significant operative time reduction with LED microscope. This evidence could be used for making the decision to switch from halogen microscope to LED microscope. Upgrading to LED-illuminated microscope might be beneficial for productivity improvement if there were at least six to seven cases operated on per day. The ultrasound time, efficacy, and safety showed no significant difference.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。