Validation and comparison between two warfarin dosing clinical algorithms and warfarin fixed dosing in specialized heart center: cross-sectional study

在专科心脏中心对两种华法林给药临床算法与华法林固定剂量方案进行验证和比较:横断面研究

阅读:2

Abstract

BACKGROUND: Warfarin is well known as a narrow therapeutic index that has prodigious variability in response which challenges dosing adjustment for the maintenance of therapeutic international normalized ratio. However, an appreciated population not on new oral anticoagulants may still need to be stabilized with warfarin dosing. OBJECTIVE: The current study's main objective was to validate and compare two models of warfarin clinical algorithm models namely the Gage and the International Warfarin Pharmacogenetics Consortium (IWPC) with warfarin 5 mg fixed standard dosing strategy in a sample of Sudanese subjects. METHOD: We have conducted a cross-sectional study recruited from the out-patient clinic at a tertiary specialized heart center. We included subjects with unchanged warfarin dose (stabilized), and with therapeutic international normalized ratio. The predicted doses of warfarin in the two models were calculated by three different methods (accuracy, clinical practicality, and the clinical safety of the clinical algorithms). MAIN OUTCOME MEASURE: The primary outcomes were the measurements of the clinical (accuracy, practicality, and safety) in each of the two clinical algorithms models compared to warfarin 5 mg fixed standard dose strategy. RESULTS: We have enrolled 71 Sudanese subjects with mean age (51.7 ± 14 years), of which (49, 69.0%) were females. There was no significant difference between the warfarin 5 mg fixed standard dose strategy and the predicted doses of the two clinical algorithm models (MAE 1.44, 1.45, and 1.49 mg/day [P =0.4]) respectively. In the clinical practicality, all of the three models had a high percent of subjects (95.0%, 51.9%, and 66.7%) in the ideal dose range in middle dose group (3-7 mg/ day) for warfarin 5 mg fixed standard dosing strategy, Gage, and IWPC clinical algorithm models respectively. However, a small percent of subjects was exhibited in the warfarin low dose group ≤ 3 mg/day (0.0%, 15.0%, and 10.0%) and warfarin high dose group ≥ 7 mg/day (0.0%, 33.3%, and 33.3%) for warfarin 5 mg fixed standard dosing strategy, Gage, and IWPC clinical algorithms respectively. In terms of clinical safety, the percent of subjects with severely over-prediction were 28.2%, 22.5%, and 22.5% for warfarin 5 mg fixed standard dosing, Gage, and IWPC, respectively. While the percent of severely under-prediction was 12.7%, 7.0%, and 5.6% for the warfarin 5 mg fixed standard dosing, Gage, and IWPC, respectively. CONCLUSION: The Gage and IWPC clinical algorithm models were accurate, more clinically practical, and clinically safe than warfarin 5 mg standard dosing in the study population. The cardiologist can use either models (Gage and IWPC) to stratify subjects for accurate, practical, and clinically safe warfarin dosing..

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。