Safety and Efficacy of Human Chorionic Gonadotropin Hormone-Derivative EA-230 in Cardiac Surgery Patients: A Randomized Double-Blind Placebo-Controlled Study

人绒毛膜促性腺激素衍生物EA-230在心脏手术患者中的安全性和有效性:一项随机双盲安慰剂对照研究

阅读:1

Abstract

OBJECTIVES: To determine the safety and efficacy of human chorionic gonadotropin hormone-derivative EA-230 in cardiac surgery patients. Cardiac surgery induces systemic inflammation and may impair renal function, affecting patient outcome. EA-230 exerted immunomodulatory and renoprotective effects in preclinical models and was safe and showed efficacy in phase I and II human studies. DESIGN: Double-blinded, placebo-controlled, randomized study. SETTING: Collaboration of the Cardiothoracic Surgery, Anesthesiology, and the Intensive Care departments of a tertiary hospital in the Netherlands. PATIENTS: One hundred eighty patients undergoing an on-pump coronary artery bypass procedure with or without concomitant valve surgery. INTERVENTIONS: Ninety mg/kg/hr EA-230 or placebo administered during surgery. MEASUREMENTS AND MAIN RESULTS: During the study, no safety concerns emerged. EA-230 did not modulate interleukin-6 plasma concentrations (area under the curve 2,730 pg/mL × hr [1,968-3,760] vs 2,680 pg/mL × hr [2,090-3,570] for EA-230 and placebo group, respectively; p = 0.80). Glomerular filtration rate increased following surgery (mean ± sem increase in the EA-230 vs placebo groups: glomerular filtration rateiohexol measured using iohexol plasma clearance: 19 ± 2 vs 16 ± 2 mL/min/1.73 m2; p = 0.13 and estimated glomerular filtration rate with the Modification of Diet in Renal Disease equation using creatinine: 6 ± 1 vs 2 ± 1 mL/min/1.73 m2; p = 0.01). The "injury" stage of the Risk, Injury, Failure, Loss of kidney function, and End-stage kidney disease criteria for acute kidney injury was 7% in the EA-230 group versus 18% in the placebo group (p = 0.07). In addition, EA-230-treated patients had a less positive fluid balance compared with placebo-treated patients (217 ± 108 vs 605 ± 103 mL; p = 0.01), while the use of vasoactive agents was similar in both groups (p = 0.39). Finally, hospital length of stay was shorter in EA-230 treated patients (8 d [7-11] vs 10 d [8-12]; p = 0.001). Efficacy results were more pronounced in patients that had longer duration of surgery and thus longer duration of study drug infusion. CONCLUSIONS: EA-230 was safe in patients undergoing on-pump cardiac surgery. It did not modulate interleukin-6 plasma concentrations but appeared to exert beneficial renal and cardiovascular effects and shortened in-hospital length of stay.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。