Synthesis of molecularly imprinted nanoparticles for selective exposure assessment of permethrin: optimization by response surface methodology

合成分子印迹纳米粒子用于氯菊酯选择性暴露评估:响应面法优化

阅读:8
作者:Omid Reza Heravizadeh, Monireh Khadem, Ramin Nabizadeh, Seyed Jamaleddin Shahtaheri

Background

Extensive use of high-efficiency pyrethroid pesticides as pest-control agents lead to remarkable adsorption and release of these materials in soil and aquatic environment which could have serious adverse effects on water and food chain quality as well as human health. In this study, a molecularly imprinted polymer was synthesized and used as a selective sorbent in the sample preparation procedure in order to facilitate sensitive and quantitative exposure assessment of insecticide permethrin.

Conclusions

The satisfactory results confirmed the reliability and efficiency of the proposed method for trace analysis of permethrin isomers in biological and environmental samples.

Methods

Molecular imprinted nanoparticles were prepared by precipitation polymerization technique using 1:4:20 mmol ratio of the template, functional monomer, and cross-linker, respectively, as well as 80 mL of chloroform as progen solvent. The obtained nanoparticles were characterized by field emission scanning electron microscopy (FESEM) and Fourier transform infrared spectrometry (FT-IR). The optimization of critical variables in the MISPE process was done using the central composite design (CCD) of the response surface methodology.

Results

Quadratic regressional models were developed to correlate the response and independent variables and the analysis of variance (ANOVA) verified the excellent fitting of proposed models for experimental data. Optimum conditions for the highest MISPE yield were selected as follow: sorbent mass of 7.71 mg, sample pH 5.58 and 5.68 for cis and trans-permethrin, respectively, sample flow rate of 0.6 mL/min, as well as 5 and 3.94 mL of methanol/acetic acid at the flow rate of 2 mL/min as elution solvents for cis and trans-permethrin, respectively. Under optimized conditions, the linear range was obtained 20-120 μg/L (R2 = 0.99) and the detection limits were 5.51 and 5.72 μg/L for cis and trans-permethrin, respectively. Analysis of real samples demonstrated the high extraction efficiency of designed protocol ranging from 93.01 to 97.14 with the relative standard deviation (RSD) less than 4.51%. Conclusions: The satisfactory results confirmed the reliability and efficiency of the proposed method for trace analysis of permethrin isomers in biological and environmental samples.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。