MRI Accurately Predicts Quadrupled Semitendinosus Autograft Size Using Posterior Hamstring Harvest for ACL Reconstruction

利用后侧腘绳肌腱进行前交叉韧带重建时,MRI可准确预测四股半腱肌自体移植的大小

阅读:2

Abstract

PURPOSE: To determine the effectiveness of preoperative magnetic resonance imaging (MRI) measurements of the cross-sectional area (CSA) of the semitendinosus tendon in predicting the intraoperative quadrupled semitendinosus graft diameter of a posteriorly harvested hamstring autograft for anterior cruciate ligament (ACL) reconstruction. METHODS: A retrospective review of patients who underwent ACL reconstruction with autograft using a posterior hamstring harvest was performed. Patient demographics and operative reports were reviewed, and measurements of the CSA of the semitendinosus on MRI were performed. Multiple linear regression was used to analyze the predictors for graft diameter. A P value < .05 was considered statistically significant. Interrater and intrarater reliability were calculated. RESULTS: 280 patients were included. Patient height (P < .0001), and CSA of the semitendinosus (P < .0001) were significant predictors. Patients shorter than 63 inches had an average graft diameter of 7.89 mm compared to 8.69 mm for patients above 63 in (P < .001). The formula for the model is as follows: Graft diameter (mm(2)) = 2.74 + .067·Height (in) + .00009 · Weight (lbs) + .0018 · Age (years) +.12·Gender (1 if M, 0 if F) + 8.56 · CSA (cm(2)). The R(2) for the model (0.5620), was greater than models using only height (R(2) = .4092) or only CSA Semitendinosus (R(2) = .3932). None of the interaction terms between covariates (e.g., height, weight, age, gender) were significant. Age (P =.6400), weight (P = .9970), and gender (P = .6700) were not significant predictors. Both intraclass (ICC = 0.864, 95% CI=[0.791, 0.912]) and interclass correlation (ICC=0.827, 95% CI=[0.715, 0.894]) showed good reliability. CONCLUSION: CSA semitendinosus tendon and patient height independently perform similarly as predictors of graft diameter. When used together, CSA and height accurately predict the graft diameter. In particular, for patients under 63 in tall who demonstrated an average graft diameter below the minimum 8 mm, as suggested by the literature, this may be a useful tool for preoperative planning of patients intending to undergo ACL reconstruction with posterior hamstring harvest. LEVEL OF EVIDENCE: Level III, diagnostic: retrospective cohort study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。