Low tidal volume ventilation strategy and organ functions in patients with pre-existing systemic inflammatory response

低潮气量通气策略和已有全身炎症反应患者的器官功能

阅读:7
作者:Vanya Chugh, Asha Tyagi, Vandna Arora, Abhay Tyagi, Shukla Das, Gargi Rai, Ashok K Sethi

Aims

Ventilation can induce increase in inflammatory mediators that may contribute to systemic organ dysfunction. Ventilation-induced organ dysfunction is likely to be accentuated if there is a pre-existing systemic inflammatory response. Material and

Background and aims

Ventilation can induce increase in inflammatory mediators that may contribute to systemic organ dysfunction. Ventilation-induced organ dysfunction is likely to be accentuated if there is a pre-existing systemic inflammatory response. Material and

Conclusions

Mechanical ventilation with low tidal volume of 6 ml/kg-1 along with PEEP of 10 cmH2O is associated with significantly worse postoperative organ functions as compared to high tidal volume of 10 ml.kg-1 in patients of perforation peritonitis-induced systemic inflammation undergoing emergency laparotomy.

Material and methods

Adult patients suffering from intestinal perforation peritonitis-induced systemic inflammatory response syndrome and scheduled for emergency laparotomy were randomized to receive intraoperative ventilation with 10 ml.kg-1 tidal volume (Group H) versus lower tidal volume of 6 ml.kg-1 along with positive end-expiratory pressure (PEEP) of 10 cmH2O (Group L), (n = 45 each). The primary outcome was postoperative organ dysfunction evaluated using the aggregate Sepsis-related Organ Failure Assessment (SOFA) score. The secondary outcomes were, inflammatory mediators viz. interleukin-6, tumor necrosis factor-α, procalcitonin, and C-reactive protein, assessed prior to (basal) and 1 h after initiation of mechanical ventilation, and 18 h postoperatively.

Methods

Adult patients suffering from intestinal perforation peritonitis-induced systemic inflammatory response syndrome and scheduled for emergency laparotomy were randomized to receive intraoperative ventilation with 10 ml.kg-1 tidal volume (Group H) versus lower tidal volume of 6 ml.kg-1 along with positive end-expiratory pressure (PEEP) of 10 cmH2O (Group L), (n = 45 each). The primary outcome was postoperative organ dysfunction evaluated using the aggregate Sepsis-related Organ Failure Assessment (SOFA) score. The secondary outcomes were, inflammatory mediators viz. interleukin-6, tumor necrosis factor-α, procalcitonin, and C-reactive protein, assessed prior to (basal) and 1 h after initiation of mechanical ventilation, and 18 h postoperatively.

Results

The aggregate SOFA score (3[1-3] vs. 1[1-3]); and that on the first postoperative day (2[1-3] vs. 1[0-3]) were higher for group L as compared to group H (P < 0.05). All inflammatory mediators were statistically similar between both groups at all time intervals (P > 0.05). Conclusions: Mechanical ventilation with low tidal volume of 6 ml/kg-1 along with PEEP of 10 cmH2O is associated with significantly worse postoperative organ functions as compared to high tidal volume of 10 ml.kg-1 in patients of perforation peritonitis-induced systemic inflammation undergoing emergency laparotomy.

特别声明

1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。

2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。

3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。

4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。