Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL-IQ) for evaluation of early bone mass changes in ageing osteoporosis patients

采用回声不对称性和最小二乘估计的迭代水脂分解法(IDEAL-IQ)评估老年骨质疏松症患者的早期骨量变化

阅读:1

Abstract

This study explored the application value of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL-IQ) technology in the early diagnosis of ageing osteoporosis (OP). 172 participants were enrolled and underwent magnetic resonance imaging (MRI) examinations on a 3.0T scanner. 100 cases were included in the normal group (50 males and 50 females; mean age: 45 years; age range: 20-84 years). 33 cases were included in the osteopenia group (17 males and 16 females; mean age: 55 years; age range: 43-83 years). 39 cases were included in the OP group (19 males and 20 females; mean age: 58 years; age range: 48-82 years). Conventional T(1)WI and T(2)WI were first obtained, followed by 3D-IDEAL-IQ-acquisition. Fat fraction (FF) and apparent transverse relaxation rate (R (2) (∗)) results were automatically calculated from IDEAL-IQ-images on the console. Based on T(1)W and T(2)W-images, 300 ROIs for each participant were manually delineated in L(1)-L(5) vertebral bodies of five middle slices. In each age group of all normal subjects, each parameter was significantly correlated with gender. In male participants from the normal, osteopenia, and OP groups, statistical analysis revealed F values of 11319.292 and 180.130 for comparisons involving FF and R (2) (∗) values, respectively (all p < 0.0001). The sensitivity and specificity of FF values were 0.906 and 0.950, 0.994 and 0.997, 0.865 and 0.820, respectively. For R (2) (∗), they were 0.665 and 0.616, 0.563 and 0.519, 0.571 and 0.368, respectively. In female participants from the normal, osteopenia, and OP-groups, statistical analysis revealed F values of 12461.658 and 548.274 for comparisons involving FF and R (2) (∗) values, respectively (all p < 0.0001). The sensitivity and specificity of FF values were 0.985 and 0.991, 0.996 and 0.996, 0.581 and 0.678, respectively. For R (2) (∗), they were 0.698 and 0.730, 0.603 and 0.665, 0.622 and 0.525, respectively. Significant differences were indicated in the quantitative values among the three groups. FF value had good performance, while R (2) (∗) value had poor performance in discriminating osteopenia and OP-groups. Overall, the IDEAL-IQ technique offers specific reference indices that enable noninvasive and quantitative assessment of lumbar vertebrae bone metabolism, thereby providing diagnostic information for OP.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。