Peritoneopericardial communication after aortic valve replacement in a peritoneal dialysis patient

腹膜透析患者主动脉瓣置换术后发生腹膜心包交通

阅读:1

Abstract

A 73-year-old male undergoing peritoneal dialysis (PD) for end-stage renal disease due to diabetic nephropathy was diagnosed with aortic stenosis and was admitted to our hospital in September, 2009. The patient underwent replacement of the ascending aorta with an artificial blood vessel plus aortic valve replacement without any notable complications. PD was restarted 3 days after the surgery and large amounts of light red fluid from the drain placed in the pericardium were observed just after resumption of PD solution. The patient was diagnosed with peritoneopericardial communication. PD was discontinued and hemodialysis was performed only with intermittent lavage of the peritoneal cavity. The amount of drainage was spontaneously decreased, and on the 17th day after surgery, PD was resumed. The patient is undergoing PD without recurrence of peritoneopericardial communication, 59 months after the onset of symptoms. Peritoneopericardial communication in a patient with PD developing after open-heart surgery is rare because such a case has been documented in only one case report. However, since massive pericardial effusion may cause severe cardiac problems, we consider that the communication between the peritoneal cavity and the pericardium needs to be checked for in patients with PD after cardiac surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。