Deployment of aortoiliac balloon-expandable covered stent via the transradial approach: report of two cases

经桡动脉入路植入主动脉髂动脉球囊扩张式覆膜支架:两例报告

阅读:1

Abstract

BACKGROUND: Endovascular therapy (EVT) for aortoiliac (AI) disease has shown favorable outcomes with recent advances in technology. Furthermore, the transradial approach (TRA) has emerged as a less invasive alternative to transfemoral access, improving patient comfort. However, data on CS implantation using the TRA remain limited. CASE PRESENTATION: We report two cases in which a VIABAHN® VBX-CS (W.L. Gore & Associates, Flagstaff, AZ, USA) were successfully deployed for AI disease using the TRA. In both cases, a 6-Fr transradial guiding sheath was used. The CSs were advanced and accurately deployed using a TRA without complications. The completion of the angiography confirmed the proper expansion and positioning of the CS. Both patients were discharged uneventfully without access-site complications. DISCUSSION: These cases demonstrate the feasibility and safety of AI balloon-expandable CS implantation using the TRA. The evolution of the device has enabled the delivery of relatively large CS using the TRA, expanding the applicability of this less invasive technique. CONCLUSION: Transradial CS treatment may be a promising procedure for AI lesions, offering both procedural safety and patient comfort.