Low energy consumption form of the U-shaped plan office building in the Yangtze River Delta

长三角地区低能耗U型平面办公楼

阅读:1

Abstract

The significance of form in green building design is well recognized, as it has a substantial impact on both energy performance and construction cost. This study investigates the impact of the U-shaped plan on the energy demand, which can be flexibly applied to irregular site forms and clustered building blocks, and is widely used in existing office buildings. Specifically, we select the U-shaped plan as the object of study and collect related case data primarily from Hangzhou and Shanghai. Using Python, we generate plans based on two lengths, two angles, and depth, which serve as basic parameters and boundary conditions. The EnergyPlus platform is utilized for dynamic simulation of the energy consumption of each model, and correlation analysis using the Spearman coefficient method identifies two planar factors (depth-length ratio and modified length) that have the most significant influence on energy consumption, including five basic parameters. Regression fitting and regression evaluation of the model further identify morphological critical information in the plan. Our research reveals that the critical interval of depth-length ratio (M1) is in (0.48, 1.02), and the critical point of the modified length (M2) is 109.38 m. Furthermore, the contour plot of M1-M2-E1 is obtained, illustrating the mutual trend between morphological parameters (M1 and M2) and annual energy use intensity, which serves as a useful aid for designing low energy consumption solutions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。