Comprehensive Radiation Shield Minimizes Operator Radiation Exposure and Obviates Need for Lead Aprons

全面的辐射防护措施最大限度地减少了操作人员的辐射暴露,并避免了使用铅围裙。

阅读:2

Abstract

BACKGROUND: The catheterization laboratory predisposes to occupational health hazards. Chronic radiation exposure (RE) direct injuries include a predilection to cataracts and concerns for cancers. Indirectly adverse effects underly the prevalence of orthopedic maladies in interventionists, linked to the burden of mandatory protective lead aprons. A novel comprehensive shielding system (Protego, Image Diagnostics Inc) has been validated in early studies to provide excellent radiation protection. The system is designed to reduce operator RE sufficient to eliminate the need for personal lead aprons. Recent system refinements offer potentially even greater degrees of protection. This clinical study evaluated the efficacy of this system. METHODS: This single-center 2-group cohort study compared physician operator RE utilizing the latest iteration of the Protego shield (n = 25 cases) or standard protection (personal leaded apparel and drop-down shield, n = 25 cases) during routine cardiac catheterization procedures. RE at both thyroid and waist levels were measured with a real-time dosimetry system (Raysafe) and calculated on a mean per case basis at both thyroid and waist levels. Additional parameters collected included procedure type, access site, per case fluoroscopy time, and patient factors including body mass index. Between-group comparisons were conducted to evaluate RE by group and measurement sites. RESULTS: Protection with Protego was superior to standard methods. Protego showed markedly lower RE at both the thyroid level (0.36 ± 0.86 vs 58.5 ± 50.2 μSv; P < .001) and the waist level (0.84 ± 2.99 vs 121.4 ± 171.2 μSv; P < .001. "Zero" total RE was documented in 68% (n = 17) of Protego cases; in contrast, standard protection did not achieve "zero" exposure in a single case. CONCLUSIONS: The Protego shield system provides excellent RE protection to the physician operator, achieving "zero" RE in two-thirds of cases. RE was superior to standard protection methods. The magnitude of protection achieves state regulatory standards sufficient to allow operators to perform procedures without orthopedically burdensome lead aprons. This shield system has the potential to reduce occupational health hazards.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。