Noise Reduction Using Singular Value Decomposition with Jensen-Shannon Divergence for Coronary Computed Tomography Angiography

利用奇异值分解和Jensen-Shannon散度进行冠状动脉计算机断层扫描血管造影的噪声抑制

阅读:1

Abstract

Coronary computed tomography angiography (CCTA) is widely used due to its improvements in computed tomography (CT) diagnostic performance. Unlike other CT examinations, CCTA requires shorter rotation times of the X-ray tube, improving the temporal resolution and facilitating the imaging of the beating heart in a stationary state. However, reconstructed CT images, including those of the coronary arteries, contain insufficient X-ray photons and considerable noise. In this study, we introduce an image-processing technique for noise reduction using singular value decomposition (SVD) for CCTA images. The threshold of SVD was determined on the basis of minimization of Jensen-Shannon (JS) divergence. Experiments were performed with various numerical phantoms and varying levels of noise to reduce noise in clinical CCTA images using the determined threshold value. The numerical phantoms produced 10% higher-quality images than the conventional noise reduction method when compared on a quantitative SSIM basis. The threshold value determined by minimizing the JS-divergence was found to be useful for efficient noise reduction in actual clinical images, depending on the level of noise.